 avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar

Watchers

 avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar  avatar

hasmartthermostat's Issues

Add to the attributes the next switch change.

Is your feature request related to a problem? Please describe.
At the moment this value is present on the HA log and I need to keep open the terminal to read the values.

Describe the solution you'd like
Would be the best having this in an attribute to read directly from the an HA lovelace card.

Describe alternatives you've considered
Value already present in the log.

Additional context
this is an example:
Time until switch.gas_miki_office turns on for Smart Miki Office (climate.smart_miki_office): 2063 sec

Time_next_change: 2036 sec.

And thank to the developer for this amazing integration. Really it works so well.

Turning off the "operation" on the thermostat does not turn off related heater switch

First of all, thank you for an excellent integration. I still have some tweaking of the parameters to do, but I love the idea and appreciate the work you have done so far.

Describe the bug
Turning the operation of the smart thermostat to "off" does not turn off configured heater switch immediately - I am not sure if it is waiting for temperature change, min_cycle_duration, or pwm period. In fact, it appears it does not attempt to switch it off at all.

To Reproduce
Steps to reproduce the behavior:
Wait for the thermostat to turn heating on, set operation to "off". Switch is not turned off immediately.

Expected behavior
I expect the configured heater switch to turn off immediately.

Additional context
Why I need it to turn off immediately:
In my setup I have z-wave relays that are "lost" when they lose power - this happens several times a day because the utility company remotely switches off heating circuits during predefined times of peak demand. I get cheaper electricity as a result.
If there are attempts to communicate with these relays during this time they get marked dead by the z-wave controller.

To prevent this from happening I turn the thermostat off preemptively using a script and predefined schedule - this makes sure the thermostat is not attempting to turn it on. I turn the thermostat back to operation mode "heat" once power is detected on related circuits.

I have been doing this for over a year using the core "generic thermostat" and have switched this week to smart thermostat and noticed this behavior. At worst I will modify my scripts to turn off the thermostats and related switches "manually".

PWM calculation

Wonderful job!
I would like to give a little advice about autotune. My autotune calculated the coefficients well, but I did not know how to define appropriate PWM. However, that it is easy enough to define - just look at the autotune graph. if I understood correctly, then the average period of time during which the heater was active is the PWM (it was ~3h with my electric Kospel ECKO). Is it worth mentioning in the documentation about the definition of PWM? I think it is possible to log it as one of autotune suggestions in the system log.

image

Preset temperatures have a hardcoded maximum value of 30°

When calling the service smart_thermostat.set_preset_temp, the new preset temperatures are not validated against the min_temp and max_temp parameters of the configuration. Instead, they appear to be validated against some fixed values. This effectively prevents the user from setting preset temperatures above 30°.

Steps to reproduce the behavior:
Sample configuration (here, the controller is used to control humidity by switching a dehumidifier, hence the high values)

climate:
  - platform: smart_thermostat
    name: Smart Thermostat Example
    unique_id: smart_thermostat_example
    heater: switch.dehumidifier
    target_sensor: sensor.humidity
    min_temp: 45
    max_temp: 80
    ac_mode: True
    target_temp: 65

Create an automation with a service call as action:

service: smart_thermostat.set_preset_temp
data:
  home_temp: 65
target:
  entity_id: climate.smart_thermostat

The following error is found when debugging the automation:

Stopped because an error was encountered at [DATE] (runtime: 0.04 seconds)

value must be at most 30 for dictionary value @ data['home_temp']

The preset temperature is not updated.

Expected behavior
The preset temperature should be updated to the indicated value (65).

Additional context
Manually changing the set point of the controller to the desired value works as expected. Specifying a preset temperature in the configuration file works as well. Only the change through the service appears to have the faulty validation.

Thank you for the excellent work on this integration!

Multiple heater entities

Hello, very good integration to control. But I have a question. Is it possible to set more entities to heater property e.g.?

heater:
switch.on_off_relay_pin_1
switch.on_off_relay_pin_2
switch.on_off_relay_pin_3
switch.on_off_relay_pin_4

Precision not working 0.1 values

Precision not working.

precision (Optional): the displayed temperature precision (valid are 0.1, 0.5 and 1.0, default 0.1 for Celsius and 1.0 for Fahrenheit)

Not working at 0.1 values

Unresponsiveness initial_hvac_mode: "off"

Despite initial hvac_mode: is set to "off" after every new ha restart it remain on the old state.
The same issue is involving target_temp: value.

Steps to reproduce the behavior:
Restart Home Assistant
OS: Raspberry PI OS
All the browser
HA ver.: core-2021.11.5

Integral part of the PID controller accumulates gain for error during the period the thermostat was in OFF state

Describe the bug
I have three floor heating circuits regulated by the Smart Thermostat. I am forced to shut them down during peak hours. When the thermostat is turned back ON (usually after 1 hour) the temperature drop is accumulated into the integral part for the whole duration it was OFF. See attached recent chart of the pid_i attribute of one of the thermostats. The flat lines are during the OFF periods, the immediate jumps are right after it is turned back on. I have highlighted the parts I am referring to.

To Reproduce
Steps to reproduce the behavior:

  1. turn thermostat OFF,
  2. wait for the temperature to drop by one or a couple of degrees over a "significant" period (from the controller perspective, i.e. an hour),
  3. turn back ON - the next pid_i update will jump by the overall accumulated error, including the off period.

Expected behavior
The integral part of the thermostat should not account for the time it has spent in the OFF state and keep the value unchanged until there is an update (temperature change / sampling period). It was obviously not missing the target temperature furing OFF period, because it could not act to achieve it.

*Screenshots
pid_i
*

Question: do nothing after start

Describe the bug
IMHO something not right, pls check.

Configured entity, restarted HA Core.
After HA started thermostat stay in Idle(Heat).
Actual temp. is 17.5, target 20, but thermostat not switching heater.

Change target to 19.5 - Idle(Heat). Set to 20 - goes to Heating(Heat).
Change back to 19.5 - again Idle(Heat).

Actual temp. all the time 17.5

  climate:
    - platform: smart_thermostat
      name: EntryR Floor ST
      unique_id: tms_entryr_floor_st
      heater: switch.rly_entryr_floor
      target_sensor: sensor.sth_entryr_floor_temperature
      min_temp: 7
      max_temp: 28
      ac_mode: False
      target_temp: 20
      keep_alive:
        seconds: 60
      away_temp: 14
      kp : 5
      ki : 0.01
      kd : 500
      pwm : 00:15:00

If thermostat waiting for new data from temperature sensor - why starts to heat if set back to 20 or more.
And not starting on target 20, if not touching it.

Expected behavior
When target/actual temp. difference is 2 degrees - heater to be switched on as soon as HA started.

Screenshots
image

Desktop (please complete the following information):

  • OS: [Windows 10]
  • Browser [Chrome]
  • Version [95.0.4638.69]

Additional context
HA Core 2021.11.5

[Feature request] Optional numerical output instead of ON/OFF

I have Radiator valves which can be controlled by a 0-100 percentage, so it would be nice if the Thermostat could also output these values, as I want to control the TRV with an external Sensor.

So a numerical output, basically just the value which is then converted to PWM, would be very useful in my setup.

I don't know how difficult this is, or if you are interested in this feature but I just wanted to suggest it as the problem came up for me.

PID is refreshed on every temperature change with sampling_period defines

Describe the bug
PID calculation is performed based on sampling_period, but also on keep_alive period.
Maybe it's the normal behavior, but, from my point of view, not.

Parameters
sampling_period: 300
keep_alice: 60

LOG

2021-12-06 21:24:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 0.00 (error = -0.10, dt = 240.00, p=-25.00, i=17.04, d=-0.00)
... ... ...
2021-12-06 21:28:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Received new temperature sensor input at timestamp 1638822530.9548683 (before 1638820465.9386318): 21.0 (before 21.1)
2021-12-06 21:28:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 0.00 (error = -0.10, dt = 60.00, p=-25.00, i=17.04, d=-0.00)
2021-12-06 21:28:50 INFO (MainThread) [custom_components.smart_thermostat.climate] Request turning off input_boolean.chauffage_sol
2021-12-06 21:28:50 INFO (MainThread) [custom_components.smart_thermostat.climate] Turning off input_boolean.chauffage_sol
2021-12-06 21:29:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 33.70 (error = 0.00, dt = 240.01, p=0.00, i=17.04, d=16.67)

PID calculation base on sampling period (strange, dt = 240, but difference from previous calculation time should be 300)
Control_output is now set to 33,70

2021-12-06 21:29:50 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns on: 537 sec
2021-12-06 21:30:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 17.04 (error = 0.00, dt = 60.00, p=0.00, i=17.04, d=-0.00)

New calculation of control_output, set now to 17,04
Time to turn on is recalculated

2021-12-06 21:30:50 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns on: 627 sec
2021-12-06 21:31:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 17.04 (error = 0.00, dt = 60.00, p=0.00, i=17.04, d=-0.00)
2021-12-06 21:31:50 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns on: 567 sec

Other log, output changes every minutes :

2021-12-06 22:03:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 55.54 (error = 0.10, dt = 60.00, p=25.00, i=30.54, d=-0.00)
2021-12-06 22:03:50 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns off: 139 sec
2021-12-06 22:04:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 66.34 (error = 0.10, dt = 240.00, p=25.00, i=41.34, d=-0.00)
2021-12-06 22:04:50 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns off: 177 sec
2021-12-06 22:05:50 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Obtained current control output. 69.04 (error = 0.10, dt = 60.00, p=25.00, i=44.04, d=-0.00)
2

Use attribute of entity for outdoor_sensor

I don't have an outdoor sensor to use but I was thinking that I could use a cloud sensor instead, such as AccuWeather. Problem is that the temperature is an attribute of the weather entity. Is it somehow possible to use it?

entity_id: weather.home
attribute: temperature

Features request PWM disabled -> Raw output

Hi,
first of all congratulations for this component. It is very useful to me.
In the old version 0.5.1 by not specifying the "pwm" parameter, the output in pwm was disabled in order to have the raw output (0 100%). I understand that it is no longer possible in the latest versions. It's correct? Now the "pwm" has a default right?
If i'm wrong please can you explain me how to do it?

In case I am right, i think having this feature could be very usefull. For instace I am controlling the temperature of my guinea pigs house with a shelly dimmer ( https://shelly.cloud/products/shelly-dimmer-2-smart-home-light-controller/ ) that drive an heat light bulb. That doesn't need to be just turned off and on but can keep all the value in the rage 0 - 100%. Imaging also a light bulb turning on and off in the cage like a disco party! Funny yes, but not always :)
Moreover this custom component can be used ( out of the box ) also for other application like illuminance controller (that is in some way what i do)
What do you think @ScratMan ?

min_cycle_duration parameter possible?

Home Assistant's generic_thermostat integration has a great parameter named min_cycle_duration which is useful to prevent damage to the heating or cooling equipment due to too often switching it on and off.

I tried your component and this is how it behaves:
kép

As you can see there are very short periods, of only a few seconds, for which the gas burner is turned off or on. This is problematic, because turning on the the gas burner is a process of at least 40-60 seconds (pump starts first for 20 seconds, pre-heats with small flame for another 20 seconds, and slowly increases flame to full afterwards). The PID algorithm makes too fast decisions, and turns on the gas for 30-40 seconds and it turns it off. Zero heat was sent to the house during during this. If this happens too fast the boiler will be damaged.

Normally one cycle of burning the gas for a central heating boiler should be at least 10 minutes, and after turning off another minimum 10 minutes should be waited before starting to burn again. This should be configurable with min_cycle_duration depending on the heating or cooling device type the user has.
Can you please add this kind of override to the component?

Question about autotune and cycle error

Hi,
I just don't get any values displayed from Autotune.
The following is always reported:

[custom_components.smart_thermostat.climate] Obtained current control output. 0.00 (error = 0.00, dt = 0.00, p=0.00, i=0.00, d=0.00) [custom_components.smart_thermostat.climate] Request turning off switch.thermostat_wohnzimmer_power (MainThread) [custom_components.smart_thermostat.climate] Reject request turning off switch.thermostat_wohnzimmer_power: Cycle is too short

i read that you should set min_cycle_duration to avoid this error, but this did not work for me either.
My config looks like this:

  • platform: smart_thermostat
    name: Smart Thermostat - Wohnzimmer
    heater: switch.thermostat_wohnzimmer_power
    target_sensor: sensor.average_wohnzimmer
    min_temp: 8
    max_temp: 28
    ac_mode: false
    target_temp: 24
    keep_alive:
    seconds: 60
    away_temp: 22
    comfort_temp: 25
    boost_temp: 26
    sleep_temp: 21.5
    home_temp: 23
    target_temp_step: 0.5
    min_cycle_duration: 00:15:00
    pwm: 00:15:00
    autotune: "ziegler-nichols"

additionally I had tried it once with "sampling_period", unfortunately also nothing. I have installed the current beta 3.
can you tell me where the error lies?
the fritz thermostats have an interval of 15 minutes, so that should fit or not?

big thanks for your help!

Output is set to 0 when temperature sensor is stable more then 3 hours

Hi @ScratMan

Unfortunately, I've got temperature sensors that send an update only when the value changes.
This night, when the PID values were stable (P:0, I:7, D:0), and the temperature also, the output suddenly cames to 0, and, cut off the heaters until the temperature drops.

This is due to these lines (#731) :

            if time.time() - self._last_sensor_update > 10800:
                # sensor not updated for more than 3 hours, considered as stall, set to 0 for safety
                self._control_output = 0

Maybe this value of "10800" should be a parameter, and, if the value is "0", this safety rule will be disabled

sleep_temp attribute change is ignored

Describe the bug
sleep_temp: 12 is ignored and reset to sleep_temp: 15

To Reproduce
Steps to reproduce the behavior:

  1. Define a smart_thermostat in .yaml with sleep_temp: 15
  2. Restart Home Assistant
  3. Edit the yaml to say sleep_temp: 12
  4. Restart Home Assistant

Expected behavior
When selecting preset "sleep" from the dropdown in the frontend thermostat, I expect the temperature to be set to 12
When checking the state in developer tools, I expect the sleep_temp: attribute to be 12

System:

  • OS: HASSio on Raspberry 3B+
  • Browser: Firefox

Additional context
I also edited the attribute from the state editor. It gets reset to 15℃ always

Can I somehow get Control Output with both positive and negative values?

Is your feature request related to a problem? Please describe.
I want to try using PID for controlling the target temperature of my heat pump. Currently it only gives either positive or negative output, and cuts out at zero.

Describe the solution you'd like
I would like to get a Control Output (using a template sensor), that works both ways.

Describe alternatives you've considered
I currently use a Python script with quasi-proportional control. I need it to warm up the surrounding air in excess, then switch to fan_only mode to spread it around the home. Otherwise it will just warm it's own surroundings to the target temperature, and everywhere else will be too cold. In the summer it's the opposite.

Additional context
I think PID is the right solution to my problem - and an elegant/cool one.

Delay in updating pid_p, pid_i and pid_d in case of target temperature changes.

I noticed that in case of modification of the "temperature" parameter (target temperature), the parameters:
pid_p:
pid_i:
pid_d:
are not updated "instantly" but the update is performed only at the first variation of the "current_temperature".

This leads to a delay in the action of the thermostat and an overshoot of the temperature in case of a decrease in target_temperature.

On/Off adjustment duration causes heater not switching on

Hi @ScratMan

I'm testing your v2021.12.5-beta3 version.
When the min_cycle_duration is greater than time_on duration, time_off duration is extended.
set_control_value starts waiting for time_off duration before switching on heaters, but, heater never switch on.

image

I think there's a bug line #949:

                if self._active:
                    _LOGGER.info("Request turning off %s", self._heater_entity_id)
                    await self._async_heater_turn_off()
                    self._time_changed = time.time()

self._time_changed is set to current time on every keep_alive cycle, when the thermostat is "_active" (and, _active is set to true when the thermostat received the fisrt temperature sensor value.

I think you should turn off heaters only when the heaters are on, by testing self._is_device_active instead if self._active:

                if self._is_device_active:
                    _LOGGER.info("Request turning off %s", self._heater_entity_id)
                    await self._async_heater_turn_off()
                    self._time_changed = time.time() 

You can also see in logs that the request to turn off heaters is called on every keep_alive cycle

2021-12-21 08:45:09 INFO (MainThread) [custom_components.smart_thermostat.climate] Reject request turning off switch.chauffage_entree: Cycle is too short
2021-12-21 08:45:39 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns on: 742 sec
2021-12-21 08:45:39 INFO (MainThread) [custom_components.smart_thermostat.climate] Request turning off switch.chauffage_entree
2021-12-21 08:45:39 INFO (MainThread) [custom_components.smart_thermostat.climate] Turning off switch.chauffage_entree
2021-12-21 08:46:09 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns on: 712 sec
2021-12-21 08:46:09 INFO (MainThread) [custom_components.smart_thermostat.climate] Request turning off switch.chauffage_entree
2021-12-21 08:46:09 INFO (MainThread) [custom_components.smart_thermostat.climate] Reject request turning off switch.chauffage_entree: Cycle is too short
2021-12-21 08:46:39 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns on: 682 sec
2021-12-21 08:46:39 INFO (MainThread) [custom_components.smart_thermostat.climate] Request turning off switch.chauffage_entree
2021-12-21 08:46:39 INFO (MainThread) [custom_components.smart_thermostat.climate] Reject request turning off switch.chauffage_entree: Cycle is too short
2021-12-21 08:47:09 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns on: 652 sec
2021-12-21 08:47:09 INFO (MainThread) [custom_components.smart_thermostat.climate] Request turning off switch.chauffage_entree
2021-12-21 08:47:09 INFO (MainThread) [custom_components.smart_thermostat.climate] Turning off switch.chauffage_entree

Regards,

Error on calling climate.set_preset_mode from an automation

Hello

I just replaced one of my generic_thermostat(s) with this smart_thermostat to experiment with and see if it could be a long term replacement for all my other thermostats, and I'm having an error fitting it with my existing automations (with node red)

I have this error when I call climate.set_preset_mode (inherited from the old generic_thermostat), any help would be much appreciated.

Testing from HA Developer Tools gives the same result

service: climate.set_preset_mode
data:
  preset_mode: none
target:
  entity_id:
    - climate.bathroom

2021-11-29 08:57:04 ERROR (SyncWorker_17) [homeassistant] Error doing job: Task exception was never retrieved
Traceback (most recent call last):
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 863, in async_request_call
    await coro
  File "/usr/src/homeassistant/homeassistant/helpers/service.py", line 704, in _handle_entity_call
    await result
  File "/config/custom_components/smart_thermostat/climate.py", line 649, in async_set_preset_mode
    self._target_temp = self.presets[preset_mode]
KeyError: 'none'

Option for setting an aditional min_cycle_duration for PID off

Is your feature request related to a problem? Please describe.
In regards to smart_thermostat.set_pid_mode service and generic usage of HASmartThermostat
Before HASmartThermostat I've used generic thermostat with min_cycle_duration of 10 seconds and hot/cold tolerance of 0.1 °C so I would get fast response when changing target_temperature. However, seting a cycle duration of 10 seconds in HASmartThermostat is not a viable option (at least for systems with big inertia like gas boilers + radiators; mine for example takes 7-8 seconds to light the flame on) because it would cause short, unnecessary cycles when the error is small. I have found that a min_cycle_duration of 10 to 15 minutes is ideeal for PID auto mode but when PID is off, with a min_cycle_duration of 15 minutes, I get big temperature fluctuations around the target temperature due to the big inertia of the system (the water in the radiators heats up to 60 °C).

Describe the solution you'd like
Adding a pid_off_min_cycle_duration parameter in the config would solve this problem.

Thanks for this awesome component!

Intermittent disruptions in temperature measurements cause huge pid_d spikes

Describe the bug
When temperature reporting device disconnects and reconnects, pid_d spikes: it results in values much larger than required by the actual derivative.

To Reproduce
Make target_sensor disconnect so that home-assistant reports it as unavailable, then reconnect. Repeat a few times if necessary.

Expected behavior
pid_d results purely from temperature measurements.

Screenshots
pid_d
image

target_sensor
image

Additional context
Used device is a Shelly 1PM wifi relay with DS18B20 temperature sensor addon. The disconnecting is a separate problem - but it appears to reveal this problem I report here. Home-assistant and hasmartthermostat are up to date.

When autotune is set and HA is restarting - >error 'SmartThermostat' object has no attribute 'pidController'

When restarting HA and autotune is set, we got an error, cause in that case, pidController did not exists.

Traceback (most recent call last):
  File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 382, in async_add_entities
    await asyncio.gather(*tasks)
  File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 607, in _async_add_entity
    await entity.add_to_platform_finish()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 714, in add_to_platform_finish
    await self.async_added_to_hass()
  File "/config/custom_components/smart_thermostat/climate.py", line 287, in async_added_to_hass
    self.pidController.integral = self.i
AttributeError: 'SmartThermostat' object has no attribute 'pidController'
2021-11-08 13:15:12 ERROR (MainThread) [homeassistant.components.climate] Error while setting up smart_thermostat platform for climate
Traceback (most recent call last):
  File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 257, in _async_setup_platform
    await asyncio.gather(*pending)
  File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 382, in async_add_entities
    await asyncio.gather(*tasks)
  File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 607, in _async_add_entity
    await entity.add_to_platform_finish()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 714, in add_to_platform_finish
    await self.async_added_to_hass()
  File "/config/custom_components/smart_thermostat/climate.py", line 287, in async_added_to_hass
    self.pidController.integral = self.i
AttributeError: 'SmartThermostat' object has no attribute 'pidController'

Attributes are not updated after a calculation

Hi,

Describe the bug
Attributes (control_output, pid_p, pid_i, pid_d) are not updated after a calculation.
Wait for a temperature update, attributes are updated.

Expected behavior
After each PID and output calculation, update attributes.

Additional context
Maybe, add at the end of "calc_output", line #804 :
await self.async_update_ha_state()

How to change presets?

I installed and configured this component successfully, but what i can only do is set a target temperature, I see no where to change the defined presets.. I want to put it into sleep mode when I'm sleeping.

Also in the entity page, it suggests "This entity ('climate.smart_thermostat_living_room') does not have a unique ID, therefore its settings cannot be managed from the UI. See the documentation for more detail."

Shared values between several thermostat

Hello,

I'm using several thermostat. Each have different settings but it seems they all shared the same limits defines in the first one.

E.g. with this:

climate:
  - platform: smart_thermostat
    name: Thermostat salon
    unique_id: smart_thermostat_salon
    heater: switch.sonoff_4ch_relay_3
    target_sensor: sensor.temperature_salon
    outdoor_sensor: sensor.wemos_teleinfo_temperature
    min_temp: 18
    max_temp: 25
    ac_mode: False
    target_temp: 21
    target_temp_step: 0.1
    keep_alive:
      seconds: 60
    away_temp: 18
    home_temp: 21
    kp: 3.6834316626861
    ki: 0.030695589940704194
    kd: 110.50177598710151
    ke: 0.6
    pwm: 00:05:00
  - platform: smart_thermostat
    name: Thermostat sous-sol
    unique_id: smart_thermostat_sous_sol
    heater: group.chauffage_sous_sol
    target_sensor: sensor.emoncms_temp_sous_sol
    outdoor_sensor: sensor.wemos_teleinfo_temperature
    min_temp: 10
    max_temp: 22
    ac_mode: False
    target_temp: 14
    target_temp_step: 0.1
    keep_alive:
      seconds: 60
    away_temp: 14
    home_temp: 19
    kp: 0.93620554759938432805225743160303
    ki: 1.929150825356307100228894101485
    kd: 131.30282805081365200932910478232
    ke: 0.6
    pwm: 00:05:00

If for example I tried to change the limits of the second one this way:

service: smart_thermostat.set_preset_temp
data:
  away_temp: 10
target:
  entity_id: climate.smart_thermostat_sous_sol

I get this error:

Logger: homeassistant.components.websocket_api.http.connection
Source: components/websocket_api/connection.py:141
Integration: Home Assistant WebSocket API (documentation, issues)
First occurred: 22:45:28 (1 occurrences)
Last logged: 22:45:28

[140471625016224] Error handling message: value must be at least 18.0 for dictionary value @ data['away_temp']. Got None

10 is supposed to be in the accepted range of the second one but he give a value of 18 which is the lower limit of the first one.

No unique_id

The generic thermostat has a unique_id property so that we can explicitly specify the id instead of getting a random one. It would be nice if we can have that in this component. :)

precision not working

Hi, great app, needed the PID
All works great, but the "precision" is not.
Cant operate in 0.1 steps.
Only in 0.5 steps

- platform: smart_thermostat name: Woonkamer heater: switch.virtual_switch_virtual_vv target_sensor: sensor.average_woonkamer_temperatuur min_temp: 19 max_temp: 24 ac_mode: False target_temp: 20.4 keep_alive: seconds: 60 kp : 30 ki : 0.005 kd : -24000 pwm: seconds: 300 precision: 0.1 away_temp: 19.3 sleep_temp: 19.8 comfort_temp: 21

Please advice

HA Restart Integral should be a float

Hello,
When restart HA, I have this error:

`Logger: homeassistant.components.climate
Source: custom_components/smart_thermostat/pid_controller/init.py:74
Integration: Thermostat (documentation, issues)
First occurred: 22:00:56 (4 occurrences)
Last logged: 22:00:56

Error adding entities for domain climate with platform smart_thermostat
Error while setting up smart_thermostat platform for climate
Traceback (most recent call last):
File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 382, in async_add_entities
await asyncio.gather(*tasks)
File "/usr/src/homeassistant/homeassistant/helpers/entity_platform.py", line 607, in _async_add_entity
await entity.add_to_platform_finish()
File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 714, in add_to_platform_finish
await self.async_added_to_hass()
File "/config/custom_components/smart_thermostat/climate.py", line 295, in async_added_to_hass
self.pidController.integral = self.i
File "/config/custom_components/smart_thermostat/pid_controller/init.py", line 74, in integral
assert isinstance(i, float), "Integral should be a float"
AssertionError: Integral should be a float`

There is no influence in my case cause Integral part is configured in yaml and not reloaded from a previous state.

[Request] Set preset temperatures at run time

Discussed in #14

Originally posted by nagyrobi November 17, 2021
One of the problems of HA's built-in generic_thermostat is that the temperature for away mode is hardcoded in the configuration, it cannot be adjusted at run time.

Thankfully smart_thermostat supports away, eco, boost, comfort, home, sleep, activity each with its own temperature value configurable.

It would be nice to have the possibility to adjust these during runtime, and use HA's history database to always restore to the last known value after restart.

Switches off on temp change

Whenever the temp changes by 0,1 the heater switches off -> on -> off, and remains off even if its below the target temp.
Also doesn't automatically turn on when below target temp.

Missing hot & cold tolerance

When PID is switched off, the thermostat acts like generic thermostat but is missing the hot and cold tolerance.

heating duration exceeds min_cycle_duration

Hi,

Be careful with float values.
My parameters:

  • keep_alive: 30
  • min_cycle_duration: 90

The heater is on more than time_on value.

In this example, time_on is too low, and, heaters will switch on for min_cycle_duration.

2021-12-22 07:57:42 INFO (MainThread) [custom_components.smart_thermostat.climate] Request turning on input_boolean.chauffage_sol
2021-12-22 07:57:42 INFO (MainThread) [custom_components.smart_thermostat.climate] Turning on input_boolean.chauffage_sol

Turning on at 7:57

2021-12-22 07:58:12 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns off: 60 sec
2021-12-22 07:58:42 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns off: 30 sec
2021-12-22 07:59:12 INFO (MainThread) [custom_components.smart_thermostat.climate] Time until input_boolean.chauffage_sol turns off: 0 sec

Should turn off (90 seconds after turning on), and, log says "0 sec", but, in fact, the heater will be switch off on next keep_alive cycle
Total heating duration is 120 seconds

2021-12-22 07:59:42 INFO (MainThread) [custom_components.smart_thermostat.climate] Request turning off input_boolean.chauffage_sol
2021-12-22 07:59:42 INFO (MainThread) [custom_components.smart_thermostat.climate] Turning off input_boolean.chauffage_sol

To have a better result, I'll change min_cycle_duration to 89 instead of 90.
but, I think this issue is due to float, time_on and time_off should be cast into integer (in seconds)

Overrride PID on Boost mode

Is your feature request related to a problem? Please describe.
It would be nice to change the Boost mode from just setting the temperature to boost_temp, to completely ignore the PID calculations and behave like a generic_thermostat, and then back to "PID" mode once the boost_temp is reached.

This will allow to really boost the temperature temporarily and go back to normal

Describe the solution you'd like
A clear and concise description of what you want to happen.

Describe alternatives you've considered
A clear and concise description of any alternative solutions or features you've considered.

Additional context
Add any other context or screenshots about the feature request here.

Thermostat is constantly switching to Off - Comfort

Whatever mode I set every 30s or so, the thermostat is set to Off - Comfort and then back to "Idle - Home" (for instance) for some seconds.
Somehow it is actually working fine, it turns on and off the switch as expected and it works like a charm (kudos for this great thermostat!!) but in the UI the behaviour is quite strange.
In this screenshot you can see how the target temperature (in purple) is constantly changing from the current preset (sleep 16, home 19, etc.) to the Comfort setting (19.5).
image

This is my config, what am I doing wrong?

  - platform: smart_thermostat
    name: Heating
    heater: switch.heating
    target_sensor: sensor.living_room_temperature
    min_temp: 15
    max_temp: 22
    ac_mode: false
    target_temp: 18
    eco_temp: 18
    home_temp: 19
    comfort_temp: 19.5
    boost_temp: 21
    away_temp: 17
    sleep_temp: 16
    cold_tolerance: 0.2
    hot_tolerance: 0
    min_cycle_duration:
      minutes: 1
    keep_alive:
      seconds: 30
    initial_hvac_mode: "off"
    precision: 0.1

Thanks in advance!

Round P / I / D / Control Output values

Hi ScratLan,

I've set a min_cycle_duration to 120 (my valve takes more than 1 minutes to be fully opened).
But, after some times, due to values with lot of number after comma, the I or D values were close to 0, but not really (0,00...),
and the output_control was very small (0,05%), and the valve was opened 2 minutes (min_cycle_duration).
My PWM is 900, so 0,05% is 0,45 secondes.

image

Value copied from developpers screen in HA :
control_output: 0.05850523519505746
pid_p: 0
pid_i: 0
pid_d: -0.0

Maybe, some values should be rounded.

Regards,

climate.set_preset_mode forces preset mode to Away

Describe the bug
climate.set_preset_mode forces preset mode to Away of I call it with preset_mode: "none" since release 2021.12.5

To Reproduce
Steps to reproduce the behavior:

  1. From HA Dev Tools
  2. Call climate.set_preset_mode with preset mode
service: climate.set_preset_mode
data: 
  preset_mode: "none"
  entity_id: "all"
  1. Thermostat is set to Away mode.

Expected behavior
A clear and concise description of what you expected to happen.

Screenshots
If applicable, add screenshots to help explain your problem.

Desktop (please complete the following information):

  • OS: [e.g. iOS]
  • Browser [e.g. chrome, safari]
  • Version [e.g. 22]

Smartphone (please complete the following information):

  • Device: [e.g. iPhone6]
  • OS: [e.g. iOS8.1]
  • Browser [e.g. stock browser, safari]
  • Version [e.g. 22]

Additional context
Reverted to 2021.12.4 and correct behavior was restored

ZeroDivisionError

After the last update my logs are flooded with this...
:(

Logger: homeassistant
Source: custom_components/smart_thermostat/climate.py:918
Integration: smart_thermostat (documentation, issues)
First occurred: 10:43:16 PM (5 occurrences)
Last logged: 10:43:17 PM

Error doing job: Task exception was never retrieved
Traceback (most recent call last):
File "/config/custom_components/smart_thermostat/climate.py", line 799, in _async_control_heating
await self.set_control_value()
File "/config/custom_components/smart_thermostat/climate.py", line 918, in set_control_value
time_off *= self._min_on_cycle_duration.seconds / time_on
ZeroDivisionError: float division by zero

Preset values not updated

After changing the preset values in the configuration.yaml the thermostat still uses the previous values.
I did restart HA.

configuration.yaml

`climate:

  • platform: smart_thermostat
    name: Smart Thermostat
    unique_id: my_smart_thermostat
    heater: switch.verwarming
    target_sensor: sensor.thermometer
    outdoor_sensor: sensor.buienradar_temperature
    preset_sync_mode: sync
    target_temp_step: 0.1
    sampling_period: 900
    min_temp: 14
    max_temp: 21
    ac_mode: False
    keep_alive:
    seconds: 60
    comfort_temp: 20
    home_temp: 19
    eco_temp: 18
    away_temp: 14
    noiseband: 0.3
    kp : 100
    ki : 40
    kd : 60
    `

Screenshot 2022-01-01 at 12 05 24

Strange behaviour after calling smart_thermostat: reload service

Describe the bug
After calling smart_thermostat: reload service I get strange behaviour of the target temperature. It always reverts to the value before reload. Only a restart of the HA core resolves this problem.

To Reproduce
Steps to reproduce the behavior:

  1. Call smart_thermostat: reload service
  2. Change the target temperature
  3. Wait a few seconds
  4. The target temperature reverts by itself to the value set before the reload

Screenshots
Untitled

Additional context
I haven't found any other cause or corelation for this behaviour. I don't have any automations or scripts or schedules or other stuff that messes with the target temperature. I've looked everywhere. The generic_thermostat works fine. Everything is fine after a HA core restart but the issue comes right back after smart_thermostat: reload service.

Integral component keeps constant in some cases

Describe the bug
A clear and concise description of what the bug is.

Integral component does not reduce when temperature is over setpoint. It keeps constant.

To Reproduce
Steps to reproduce the behavior:
Change setpoint under actual temperature

Expected behavior
It should reduce itself to 0 smoothly.

Screenshots
If applicable, add screenshots to help explain your problem.

Desktop (please complete the following information):

  • OS: [e.g. iOS]
  • Browser [e.g. chrome, safari]
  • Version [e.g. 22]
    N/A

Smartphone (please complete the following information):

  • Device: [e.g. iPhone6]
  • OS: [e.g. iOS8.1]
  • Browser [e.g. stock browser, safari]
  • Version [e.g. 22]
    N/A

Additional context
The problem can be solved changing this line in pid_controller/init.py:

if self._out_min < self._last_output < self._out_max and \
to:
if self._out_min <= self._last_output <= self._out_max and \

As it is now, when output falls to 0 and do not change, the integral component do not vary.

Configure Guidelines for a Zigbee Thermostat

Currently Running v2021.11.9-beta2

Looking to configure a existing Zigbee Thermostat for use with the HASmartThermostat.

Looks like its having some issues handling how to gets the current temp.

I have attached a screenshot of how the Thermostat is currently listed in devtools
image

The logs show the following

2021-11-29 13:50:42 DEBUG (MainThread) [custom_components.smart_thermostat.climate] PID Gains: kp = 75.0, ki = 0.001, kd = 70000.0
2021-11-29 13:50:44 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Unable to update from sensor: could not convert string to float: 'heat'
2021-11-29 13:50:44 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Received new temperature sensor input at timestamp 1638211844.2949722 (before None): None (before None)
2021-11-29 13:50:44 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Unable to update from sensor: could not convert string to float: 'heat'
2021-11-29 13:53:15 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Unable to update from sensor: could not convert string to float: 'heat'
2021-11-29 13:53:15 DEBUG (MainThread) [custom_components.smart_thermostat.climate] Received new temperature sensor input at timestamp 1638211995.5093408 (before 1638211844.2949722): None (before None)

and here is the config I'm using:

climate:
  - platform: smart_thermostat
    name: Smart Thermostat
    heater: climate.homehvac_1d6a2c0b_fan_thermostat
    target_sensor: climate.homehvac_1d6a2c0b_fan_thermostat
    min_temp: 44.6
    max_temp: 89.6
    ac_mode: False
    target_temp: 69
    unique_id: homesmartthermostat
    keep_alive:
      seconds: 60
    away_temp: 65
    kp: 75
    ki: 0.001
    kd: 70000
    pwm: 00:15:00

(Update: Looks like complicated templates are going to be required for this)

Preset remains unchanged after changing target temperature

If a preset is activated, when manually changing the target temperature the preset should be automatically changed to "none" but actually it remains unchanged.

To Reproduce
Steps to reproduce the behavior:

  1. Activate a preset
  2. Change target temperature
  3. The preset remains the same instead of switching to "none"

This behaviour creates confusion among users and problems for schedules and automations. Would be useful if it would change to "none". Or even better, keep in sync with target temperature.

Responsiveness is slow

When I change the preferred temp it always takes a while to turn off or on.
I noticed it's exactly 5 min, which is what I have set in the sampling period parameter.
Is this a bug or expected behavior?

I remember it use to respond directly to user input.

float division by zero

Bonjour,

J'essaye de calibrer deux thermostats et j'obtiens les erreurs suivantes:

Describe the bug

Logger: homeassistant.components.websocket_api.http.connection
Source: custom_components/smart_thermostat/pid_controller/__init__.py:305
Integration: Home Assistant WebSocket API (documentation, issues)
First occurred: 06:48:48 (2 occurrences)
Last logged: 06:48:53

[140041979602688] float division by zero
Traceback (most recent call last):
  File "/usr/src/homeassistant/homeassistant/components/websocket_api/commands.py", line 185, in handle_call_service
    await hass.services.async_call(
  File "/usr/src/homeassistant/homeassistant/core.py", line 1495, in async_call
    task.result()
  File "/usr/src/homeassistant/homeassistant/core.py", line 1530, in _execute_service
    await handler.job.target(service_call)
  File "/usr/src/homeassistant/homeassistant/helpers/entity_component.py", line 209, in handle_service
    await self.hass.helpers.service.entity_service_call(
  File "/usr/src/homeassistant/homeassistant/helpers/service.py", line 663, in entity_service_call
    future.result()  # pop exception if have
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 896, in async_request_call
    await coro
  File "/usr/src/homeassistant/homeassistant/helpers/service.py", line 700, in _handle_entity_call
    await result
  File "/config/custom_components/smart_thermostat/climate.py", line 646, in async_set_hvac_mode
    await self._async_control_heating(calc_pid=True)
  File "/config/custom_components/smart_thermostat/climate.py", line 823, in _async_control_heating
    await self.async_update_ha_state()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 492, in async_update_ha_state
    self._async_write_ha_state()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 541, in _async_write_ha_state
    extra_state_attributes = self.extra_state_attributes
  File "/config/custom_components/smart_thermostat/climate.py", line 621, in extra_state_attributes
    "autotune_buffer_full": round(self._pidAutotune.buffer_full, 2),
  File "/config/custom_components/smart_thermostat/pid_controller/__init__.py", line 305, in buffer_full
    return len(self._inputs) / float(self._inputs.maxlen)
ZeroDivisionError: float division by zero
Cette erreur provient d'une intégration personnalisée

Logger: homeassistant.helpers.event
Source: custom_components/smart_thermostat/pid_controller/__init__.py:305
Integration: smart_thermostat (documentation, issues)
First occurred: 06:19:07 (14 occurrences)
Last logged: 08:23:07

Error while processing state change for switch.sonoff_4ch_relay_4
Traceback (most recent call last):
  File "/usr/src/homeassistant/homeassistant/helpers/event.py", line 269, in _async_state_change_dispatcher
    hass.async_run_hass_job(job, event)
  File "/usr/src/homeassistant/homeassistant/core.py", line 433, in async_run_hass_job
    hassjob.target(*args)
  File "/usr/src/homeassistant/homeassistant/helpers/event.py", line 209, in state_change_listener
    state_change_dispatcher(event)
  File "/usr/src/homeassistant/homeassistant/helpers/event.py", line 196, in state_change_dispatcher
    hass.async_run_hass_job(
  File "/usr/src/homeassistant/homeassistant/core.py", line 433, in async_run_hass_job
    hassjob.target(*args)
  File "/config/custom_components/smart_thermostat/climate.py", line 783, in _async_switch_changed
    self.async_schedule_update_ha_state()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 660, in async_schedule_update_ha_state
    self.async_write_ha_state()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 505, in async_write_ha_state
    self._async_write_ha_state()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 541, in _async_write_ha_state
    extra_state_attributes = self.extra_state_attributes
  File "/config/custom_components/smart_thermostat/climate.py", line 621, in extra_state_attributes
    "autotune_buffer_full": round(self._pidAutotune.buffer_full, 2),
  File "/config/custom_components/smart_thermostat/pid_controller/__init__.py", line 305, in buffer_full
    return len(self._inputs) / float(self._inputs.maxlen)
ZeroDivisionError: float division by zero
Cette erreur provient d'une intégration personnalisée

Logger: homeassistant
Source: custom_components/smart_thermostat/pid_controller/__init__.py:305
Integration: smart_thermostat (documentation, issues)
First occurred: 06:19:07 (355 occurrences)
Last logged: 08:36:47

Error doing job: Task exception was never retrieved
Traceback (most recent call last):
  File "/config/custom_components/smart_thermostat/climate.py", line 765, in _async_sensor_changed
    await self._async_control_heating(calc_pid=True)
  File "/config/custom_components/smart_thermostat/climate.py", line 823, in _async_control_heating
    await self.async_update_ha_state()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 492, in async_update_ha_state
    self._async_write_ha_state()
  File "/usr/src/homeassistant/homeassistant/helpers/entity.py", line 541, in _async_write_ha_state
    extra_state_attributes = self.extra_state_attributes
  File "/config/custom_components/smart_thermostat/climate.py", line 621, in extra_state_attributes
    "autotune_buffer_full": round(self._pidAutotune.buffer_full, 2),
  File "/config/custom_components/smart_thermostat/pid_controller/__init__.py", line 305, in buffer_full
    return len(self._inputs) / float(self._inputs.maxlen)
ZeroDivisionError: float division by zero

To Reproduce

climate:
  - platform: smart_thermostat
    name: Thermostat salon
    unique_id: smart_thermostat_salon
    heater: switch.sonoff_4ch_relay_3
    target_sensor: sensor.temperature_salon
    outdoor_sensor: sensor.wemos_teleinfo_temperature
    min_temp: 18
    max_temp: 25
    ac_mode: False
    target_temp: 21
    target_temp_step: 0.1
    keep_alive:
      seconds: 60
    away_temp: 18
    kp: 3.6834316626861
    ki: 0.030695589940704194
    kd: 110.50177598710151
    ke: 0.01
    pwm: 00:15:00
    autotune: "ziegler-nichols"
    lookback: 02:00:00
    noiseband: 0.2
  - platform: smart_thermostat
    name: Thermostat bureau
    unique_id: smart_thermostat_bureau
    heater: switch.sonoff_4ch_relay_4
    target_sensor: sensor.temperature_bureau
    outdoor_sensor: sensor.wemos_teleinfo_temperature
    min_temp: 18
    max_temp: 25
    ac_mode: False
    target_temp: 21
    target_temp_step: 0.1
    keep_alive:
      seconds: 60
    away_temp: 18
    kp: 5
    ki: 0.01
    kd: 500
    ke: 0.01
    pwm: 00:15:00
    autotune: "ziegler-nichols"
    lookback: 0024:00:00
    noiseband: 0.2

Merci !

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. 📊📈🎉

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❤️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.