ddffnn avatar ddffnn commented on August 17, 2024 1

I looked at the meter today to read it directly and realized it's new too. The old meter was mechanical, but this new one is ultrasonic with a nine-digit digital display. It alternates showing total volume and instantaneous rate.

2024-07-09-08-01-37-488
2024-07-09-08-00-09-801

Anyway, I read the meter manually three times, and we only used water during a few periods so there were only 7 unique payloads.

{273}555555555555557631763175f08ecd76b6a526f438c99d3c11ab85576716ec3e9fa70
{274}555555555555557631763175f08ecd76b6a526f438c99d3e91ab85576716ec3e90570
{272}555555555555557631763175f08ecd76b6a526f438c99d2791ab85576716ec3e8336  [4614.36]
{277}555555555555557631763175f08ecd76b6a526f438c99d0711ab85576716ec3e8c0420 [4620.64]
{275}555555555555557631763175f08ecd76b6a526f438c99d0110ab85576716ec3e89420
{273}555555555555557631763175f08ecd76b6a526f438c99d0e902b85576716ec3ee2508 [4695.78]
{275}555555555555557631763175f08ecd76b6a526f438c99d56102b85576716ec3eac658

I messed around in BitBench but I'm starting to wonder if there is some 3of6 still in use or something similar. I can't find the serial number or get increasing values, let alone values that match my manual readings.

from rtl_433.

zuckschwerdt avatar zuckschwerdt commented on August 17, 2024

The codes look promising but not like we expect for the Badger ORION. The start looks like a sync word of 7631 7631 or d8c5 d8c5 or 273a 273a or 89ce 89ce (shift and invert however you like…) and the end looks like what could be a CRC-16. But alignment is not clear to me and I can't see if there is a 3of6 coding present?

from rtl_433.

ddffnn avatar ddffnn commented on August 17, 2024

Yes, I agree on all those points. Also, it's longer than we would expect. I've been trying different antennas, frequencies, and dongles, but I've never seen my water meter using 223. I kept thinking I'm doing something wrong, but it sure seems like the protocol had just changed.

I plan to read the analog display of the encoder today. It used to match with the old module so I can only assume it will with this one also.

from rtl_433.

ddffnn avatar ddffnn commented on August 17, 2024

@nickovs Since you did the work for protocol 223, do you happen to have any suggestions for this one?

from rtl_433.

Related Issues (20)

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    πŸ–– Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. πŸ“ŠπŸ“ˆπŸŽ‰

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google ❀️ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.