Git Product home page Git Product logo

daikin-control's Introduction

Daikin-Control

Web Gui Preview

The '''Daikin Emura FTXG-L''' air conditioner comes with a wifi module preinstalled that allows you to control it via internet. The solution provided by Daikin is a mobile app (very well designed) that allows you to control the air conditioner even remotely, exploiting the REST API of the wifi module.

Even if the system works, there are some problems:

  • It is no possible to control the AC from a web browser. You must use the official mobile application. If your device is not supported or you are from a computer you can not control your air conditioner over the internet.
  • To control your AC remotely from outside your lan, your requests must go through the Daikin server. The device response is slow because the system is based on polling request. (you can't set the ip of the AC on the mobile application)
  • Even if the remote management system involves the use of an account with password, there is a big security issue, password and username can be accessed from inside your LAN with a GET request. (try basic_info request)

This project aims to provide 2 main things:

  • unoffcial documentation of Daikin API needed to control the air conditioner
  • web interface to manage air conditioner settings

##Tested Hardware

Throughout this document is to be considered valid for the following hardware configuration

ModelName:          Daikin Emura FTXG-L
ModelID:            FTXG35LV1BW
WifiControllerID:   BRP069A41 4P358711-2C
Software version:   1.4.3

Please contact me if you try new configurations.

##API System

Daikin original API use REST.

You can use GET http request to retrive informations and POST http request to apply new settings.

Uri GET POST desc
/common/basic_info X Provides Daikin account information (security issue!), software version, mac address and generic info
/common/get_remote_method X Provides information about polling system
/common/set_remote_method X Set information on the polling system (reduce remote time update ??)
/aircon/get_model_info X Provides model informarion
/aircon/get_control_info X Main Uri to request all current status parameters
/aircon/set_control_info X Main Uri to set status parameters ( control almost all)
/aircon/get_sensor_info X Provides information on temperatures and sensors
/aircon/get_timer X ?
/aircon/set_timer X ?
/aircon/get_price X ?
/aircon/set_price X ?
/aircon/get_target X ?
/aircon/set_target X ?
/aircon/get_week_power X Provides weekly runtime information
/aircon/get_year_power X Provides yearly runtime information
/aircon/get_program X ?
/aircon/set_program X ?
/aircon/get_scdltimer X Provides information about on/off weekly timer
/aircon/set_scdltimer X Set information about on/off weekly timer
/common/get_notify X ?
/common/set_notify X ?
/common/set_regioncode X ?
/common/set_led X ?

##Parameters

###"/common/set_control_info"

####Power param name : pow

description: represents the power state of the device

value desc
0 OFF
1 ON

####Mode param name : mode

description: represents the operating mode

value desc
2 DEHUMDIFICATOR
3 COLD
4 HOT
6 FAN
0-1-7 AUTO

####Temp param name : stemp

description: represents the target temperature

general accepted range 10-41

mode accepted range
AUTO 18-31
HOT 10-31
COLD 18-33

device memorize last target temp state for each mode under dft* (dft1,dft2...) parameters. You can't set directly these.

####Fan rate param name : f_rate

description: represents the fan rate mode

value desc
A auto
B silence
3 lvl_1
4 lvl_2
5 lvl_3
6 lvl_4
7 lvl_5

device memorize last fan rate state for each mode under dfr* (dfr1,dfr2...) parameters. You can't set directly these.

####Fan direction param name : f_dir

description: represents the fan direction

value desc
0 all wings stopped
1 vertical wings motion
2 horizontal wings motion
3 vertical and horizontal wings motion

device memorize last fan rate state for each mode under dfd* (dfd1,dfd2...) parameters. You can't set directly these.

####Humidity param name : shum

description: represents the target humidity

Daikin Emura FTXG-L does not support humidity related functionality.

device memorize last humidity state for each mode under dh* (dh1,dh2...) parameters. You can't set directly these.


Posting to set_control_info you can omit these param:

  • adv
  • dt*
  • dh*
  • dfr*
  • dfd*
  • b_mode
  • b_stemp
  • b_shum
  • b_f_rate
  • b_f_dir
  • alert

minimal request example: pow=1&mode=1&stemp=26&shum=0&f_rate=B&f_dir=3

###"/common/set_led" ####Led It seems that this settings doesn't actually change led.

param name: led

value desc
  • | set to '0' (same as '0' value) 0 | ? 1 | ?

##Unsupported settings This list show which hardware functionality are not supported by API

  • led brightness switch

##Useful resource

##Control Info Examples

Switched Off

ret=OK,pow=0,mode=7,adv=,stemp=24.0,shum=0,dt1=24.0,dt2=M,dt3=25.0,dt4=25.0,dt5=25.0,dt7=24.0,dh1=0,dh2=50,dh3=0,dh4=0,dh5=0,dh7=0,dhh=50,b_mode=7,b_stemp=24.0,b_shum=0,alert=255,f_rate=4,f_dir=0,b_f_rate=4,b_f_dir=0,dfr1=4,dfr2=5,dfr3=7,dfr4=5,dfr5=5,dfr6=5,dfr7=4,dfrh=5,dfd1=0,dfd2=0,dfd3=3,dfd4=0,dfd5=0,dfd6=0,dfd7=0,dfdh=0

Auto 25C ( CONFORT AIR ) ( INTELLIGENT EYE )

ret=OK,pow=1,mode=7,adv=,stemp=25.0,shum=0,dt1=25.0,dt2=M,dt3=22.0,dt4=25.0,dt5=25.0,dt7=25.0,dh1=0,dh2=50,dh3=0,dh4=0,dh5=0,dh7=0,dhh=50,b_mode=7,b_stemp=25.0,b_shum=0,alert=255,f_rate=A,f_dir=0,b_f_rate=4,b_f_dir=0,dfr1=4,dfr2=5,dfr3=4,dfr4=5,dfr5=5,dfr6=5,dfr7=4,dfrh=5,dfd1=0,dfd2=0,dfd3=0,dfd4=0,dfd5=0,dfd6=0,dfd7=0,dfdh=0
ret=OK,pow=1&dh2=50&dfd4=0&b_stemp=25.0&alert=255&f_dir=0&b_shum=0&dh4=0&dfd3=0&dh3=0&dfd2=0&dfr2=5&dfr7=B&dfr4=5&dfd7=0&dfrh=5&dt3=25.0&dfdh=0&adv=&dh5=0&dh1=0&dfr6=5&dt5=25.0&dfr1=B&stemp=25.0&shum=0&dfd6=0&f_rate=A&b_f_dir=0&dt1=25.0&dhh=50&dfd1=0&dfr3=5&dh7=0&mode=1&dfd5=0&b_mode=7&dt4=25.0&b_f_rate=A&dt7=25.0&dt2=M&dfr5=5 

Hot 25c ( AIR silence )

ret=OK,pow=1,mode=4,adv=,stemp=25.0,shum=0,dt1=25.0,dt2=M,dt3=22.0,dt4=25.0,dt5=25.0,dt7=25.0,dh1=0,dh2=50,dh3=0,dh4=0,dh5=0,dh7=0,dhh=50,b_mode=4,b_stemp=25.0,b_shum=0,alert=255,f_rate=B,f_dir=0,b_f_rate=B,b_f_dir=0,dfr1=B,dfr2=B,dfr3=B,dfr4=B,dfr5=B,dfr6=B,dfr7=B,dfrh=5,dfd1=0,dfd2=0,dfd3=0,dfd4=0,dfd5=0,dfd6=0,dfd7=0,dfdh=0

daikin-control's People

Contributors

ael-code avatar

Recommend Projects

  • React photo React

    A declarative, efficient, and flexible JavaScript library for building user interfaces.

  • Vue.js photo Vue.js

    ๐Ÿ–– Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.

  • Typescript photo Typescript

    TypeScript is a superset of JavaScript that compiles to clean JavaScript output.

  • TensorFlow photo TensorFlow

    An Open Source Machine Learning Framework for Everyone

  • Django photo Django

    The Web framework for perfectionists with deadlines.

  • D3 photo D3

    Bring data to life with SVG, Canvas and HTML. ๐Ÿ“Š๐Ÿ“ˆ๐ŸŽ‰

Recommend Topics

  • javascript

    JavaScript (JS) is a lightweight interpreted programming language with first-class functions.

  • web

    Some thing interesting about web. New door for the world.

  • server

    A server is a program made to process requests and deliver data to clients.

  • Machine learning

    Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.

  • Game

    Some thing interesting about game, make everyone happy.

Recommend Org

  • Facebook photo Facebook

    We are working to build community through open source technology. NB: members must have two-factor auth.

  • Microsoft photo Microsoft

    Open source projects and samples from Microsoft.

  • Google photo Google

    Google โค๏ธ Open Source for everyone.

  • D3 photo D3

    Data-Driven Documents codes.