The update is working without problems.
Thank you for the good work - this tool really help me to find out, what is wrong with my Ariston Alteas One Net.
The short-cycling is better - it is now forced to be off for at least 7 min. and the pattern of the Flame On graf shows it very nice.
I will now buy some temperature sensor to balance the 3 zones as good as possibly.
from ariston-remotethermo-home-assistant-v3.
The 10 DS18B20 is working and I will put them on the pipes later. I am waiting for a case for my new Rpi4.
Today I tried the beta update, but it didn't worked, so I went back to v. 6 - I'm happy, that the hack is working, so it is easy to change.
from ariston-remotethermo-home-assistant-v3.
I found the resolution to the problem!
The central heater thermostat is in the hallway, where I only want a temperature between 20 and 20.5
In the living room I want a temperature of more than 20.8
In the living room I have a AeoTec temperature sensor for reading the temperature and I use this device for a trigger for my automations.
I made, as a start, two automations - one for start and one for stop.
The Actions part I made is, for now, as follows.
The short-cyling problem are solved, so I will close the subject!
from ariston-remotethermo-home-assistant-v3.
Hey LeifRas! Thank you for the feedback. The sort-cycling sounds dangerous I hope you can fix it.
I use DHW (domestic hot water) operation disabled with fixed 55 degree. This setting is only for hot water. So I have to wait a little when I open the hot water tap to actually have the required water temperature, but it consumes less gas.
The automatic thermoregulation is for CH (central heating). When it is on, the device chooses the flow setpoint temperature (temperature of the water when it starts circulating) automatically. I turned it on for my device.
from ariston-remotethermo-home-assistant-v3.
Hi
I found a solution in the Ariston Alteas One technical Area menu.
In menu 2.3.5 I changed CH Anti-cycling time mode to 0 - 0=Manual
In menu 2.3.6 I changed the Anti-cycling time to the Max 7 - from 0 to 7 (minuttes)=7
It only regulates the off time, so it always stays off for at least 7 min and heat for 1 or more minutes.
I made a lot of tests with the help of your program and found out that this was the only solution.
I tried with fixed temperature without any thermostat - it was short-cycling. It didn't matters if I used auto mode or not.
I tried a lot. Higher water pressure, removing air form radiators etc.
I think it has something to do with the installation og the pipes - there size, radiator dimensions, old radiator thermostats (some of them mounted wrongly in a up/down orientation), a needed cleaning the hole system etc.
I am not a plumber, so I will have at look at it, when it will be spring ;-)
Yes - I am sure, that it is bad for the device!
It must have been like that for more than 4 years until the PCB broke down - it was dark where the cabling to the ingnition electrode was connected to the PCB, so there was sign of comming sparks from a capacitor on the PCB to ground.
We have 7 years garanti, so until now it was repaired without costs.
from ariston-remotethermo-home-assistant-v3.
Wow It is good to know. I don't have these menu items for my device. Good luck with that!
from ariston-remotethermo-home-assistant-v3.
Sorry I have to ask again.
I have now installed HACKS, but I don't know, what to search for to update ariston-remothermo?
My Ariston has been down twice, with an error 104 - Insufficient Circulation.
I think that the pump is running to slow - it is maybe running slow because og dirty circulation water?
I was ajusting som valves and I think the new problem started at that time.
from ariston-remotethermo-home-assistant-v3.
Ohh - I found out.
I tried to add a custom repository and then it found Ariston Net and installed that...
from ariston-remotethermo-home-assistant-v3.
@LeifRas: For beta you should delete and readd the integration because it uses a different api call to get the device.
from ariston-remotethermo-home-assistant-v3.
OK - I did that and now it is working. I have 4 entities, that is now not available, but the most part is working fine. Thank you.
from ariston-remotethermo-home-assistant-v3.
I still have problems with short-cycling. It's because I don't want to use the default Ariston Cube rf thermostat, as the variation in the temperature is over 0,5 degree Celsius. The heater just turns of, when the pressure is to hight.
There should be a possibility to include some code from core to control the short-cycling - look here:
home-assistant/core#2726
Will you use a little time to look at it and tell me, if it possibly?
Thank you.
from ariston-remotethermo-home-assistant-v3.
I am now working on using my Aeotec termometer ZWA039-C to change the HVAC mode on and off.
I have made two automations, but it does't seems to work all the time - maybe my logik in the settings are incorrect.
from ariston-remotethermo-home-assistant-v3.
Now my automatisation is working - I have a HueLight turning on and off.
There is a problem with the Ariston - I think I need a HVAC=idle.
With Off - it turns the heater off, and I have to manually turn it on again.
With Auto - I don't know what that is for, but I also have to manually turn it on again.
But thank you for your effort - I can make a lot of very good statistics - it help me a lot in making a solution for the short-cycling!
from ariston-remotethermo-home-assistant-v3.
That's great news!
from ariston-remotethermo-home-assistant-v3.
Related Issues (20)
- LydosHybrid: add anti cooling temperature
- Change anti cooling temperature icon
- Watersettings are missing HOT 1
- Water Heater don't show up HOT 21
- Integration fails to load HOT 2
- Problem with update core 2024.2.1 HOT 17
- Tips for getting started on similar integration
- Feature request: Please add CH return flow temperature. HOT 10
- [FEATURE] LydosHybrid: add night mode
- [BUG] HVACMode warnings for ariston climate HOT 3
- [FEATURE] Add anti-legionella cycle
- [FEATURE] Better Evo support
- [FEATURE] Add proc req temp HOT 1
- Flame on is "unknown", climate (ch) state is "idle" while heat pump is working HOT 3
- Heat Pump Sensor State HOT 2
- [BUG] Ariston Integration is not stable HOT 3
- Support for the ELCO AEROTOP MONO 15X.2
- custom_components.ariston error HA 2024.4.1 HOT 21
- [FEATURE] Ariston Genus One+ - start and stop appliance HOT 1
- [BUG] Device/entity does not show up in climate service HOT 1
Recommend Projects
-
React
A declarative, efficient, and flexible JavaScript library for building user interfaces.
-
Vue.js
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
-
Typescript
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
-
TensorFlow
An Open Source Machine Learning Framework for Everyone
-
Django
The Web framework for perfectionists with deadlines.
-
Laravel
A PHP framework for web artisans
-
D3
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
-
Recommend Topics
-
javascript
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
-
web
Some thing interesting about web. New door for the world.
-
server
A server is a program made to process requests and deliver data to clients.
-
Machine learning
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
-
Visualization
Some thing interesting about visualization, use data art
-
Game
Some thing interesting about game, make everyone happy.
Recommend Org
-
Facebook
We are working to build community through open source technology. NB: members must have two-factor auth.
-
Microsoft
Open source projects and samples from Microsoft.
-
Google
Google ❤️ Open Source for everyone.
-
Alibaba
Alibaba Open Source for everyone
-
D3
Data-Driven Documents codes.
-
Tencent
China tencent open source team.
from ariston-remotethermo-home-assistant-v3.