Most datasheets of modbus-capable devices show the addresses in hexadecimal. It would be nice if the same number base could be used in the tools.
the window size is bigger than my laptop screen and i can't show below side and can't scroll down!
I have Master in RTU mode. The UI becomes unresponsive (blocks) when there is no slave response after clicking Read coils or any other button. You should probably have a timeout as per Modbus spec.
Although DataTab.DataLength getter has code to handle hexadecimal entries, the MaxLength property of txtSize = 3 effectly blocks using that feature. The setter will use decimal representations only.
Hello once again, @graham22!
Similar to #4. A Non spec-compliant PDU is returned for the "Write Single Register" call when using the "Modbus Slave" tool.
Section 6.6 "06 (0x06) Write Single Register" of the Modbus Application Protocol document states the following:
The normal response is an echo of the request, returned after the register contents have been
written.
Writing a value 0xAAAA
to address 0x0000
using the "Write Single Register" Modbus function, the Modbus Slave tool sends me the following response (copied from the Communication log): TX: 00 01 00 00 00 06 01 06 00 00 00 01
Manually decoding it leads to the following:
Transaction ID: 0x0001
Protocol ID: 0x0000
Length: 0x0006
Unit ID: 0x01
Function Code: 0x06
Register Address: 0x0000
Register Value: 0x0001
The Register Value
field is not equal to the written value (0xAAAA
).
Going through the code, the bug seems to be in this file in the ServerEncode
method. Instead of the written register value being pushed into the message, the message header is (using the PushRequestHeader
function). This deviates from the specification.
public override void ServerDecode(
ModbusCommand command,
ByteArrayReader body)
{
ModbusCodecBase.PopRequestHeader(
command,
body);
//var count = body.ReadByte() / 2;
var count = body.ReadByte();
command.Data = new ushort[count];
command.QueryTotalLength += (count + 3);
for (int i = 0; i < count; i++)
command.Data[i] = body.ReadUInt16BE();
}
Is it possible to dump the logs to a file?
need also 28800 Boudrate ,
would be easy to let the fields writable far all the fields
and resiszeable ,
and cut the data alowed would be nice
thanx
Correctly connected to the slave device. Tried to read registers and everything was ok. Then I selected "write single register" without pressing "Apply" and from that moment I'm no more able to read anything more...not even in Home Assistant, all sensors are now unavailable!!!
Please help me to solve this issue
I'm having issue sending command to my slave. I got this error from the console.
The strange thing is that data on the slave are correctly writte on the register when I run the write multiple register.
For istance, if I try to write on the register 29 the number 5, the Modbus Master send the string over serial (I'm using MODBUS RTU with an USB-RS485 adapter)
01 10 00 1D 00 01 02 00 05 65 DE
And I got the response
00 7f f7 c5 ff fd dd c2 00
and the Error code 2
Why the write goes well as I can see the register get updated with the data I requested to write but I got this error?
How do I send the command to the device?
I need to send 010301010040 command without bcc ..
Unfortunately, I am writing this issue at the office away from the machine on which this happened. Therefore, the only information i got is from my own memory. However, I am quite sure it was caused by something on my laptop.
What would happen is if I tried to read an input or holding register I would get the message "Established connection was aborted by host"
If I would set the action to poll (interval of 2000) and then reconnect, it would read the first 2 intervals fine and then return the same error.
Any idea on what might cause this?
When I try to make registers of different type it set all values to zero. How can I have multiple registers of different types in one simulator?
Hello @graham22!
First of all thank you for writing this tool, it's been very helpful during development of my own Modbus TCP implementation!
I came across something which deviates from the Modbus Protocol specification in the Modbus Slave tool (server):
When I write a single coil with value 0xFF00
at address 0x0000
, the following message gets sent back to me (I have copied it from the Communication Log): TX: 00 10 00 00 00 06 01 05 00 00 00 01
.
Manually decoding the message according to the Modbus Protocol spec using the "Modbus Application Protocol" document - section 6.5 "05 (0x05) Write Single Coil" leads to the following:
Transaction ID: 0x0010
Protocol ID: 0x0000
Length: 0x0006
Unit ID: 0x01
Function Code: 0x05
Output Address: 0x0000
Output Value: 0x0001
The part that's off is the "Output Value" field (the last 2 bytes of the message). According to spec this has to be either 0x0000
or 0xFF00
depending on what value was written to the coil. The returned value is neither of those two (and from my testing, is always 0x0001
regardless of whether a high or low value is written).
I have tried to figure out where this problem arises from, and I have been able to narrow it down to this file. Looking at the ServerEncode
function, instead of the written value being pushed into the message, the message header is (using the PushRequestHeader
function). This deviates from the specification.
Dear Graham,
Thanks a lot for writing a Software and making it available here.
Before I try and explore its capabilities I wanted to ask one question.
I am looking for a piece of Software that can read as a Master via Modbus TCP data from 3 Slaves each with its own IP address and that then can give out the read data via Modbus Slave (or Master if Slave is not possible) on a single IP address.
The idea is to bundle the information from 3 IP adresses to just 1 IP address.
Can you tell me if your Software can do this?
Or do you maybe know a Software that can do this? ( ;-) )
Your time of even reading this message is very much appreciated so thanks a lot again for your software and in advance also for your answer,
Chris
I've connected two instances of modbusmaster to a single modbus slave like this:
When I then do a read holding registers from the first modbus master, the log window of the second modbusmaster stays empty.
Can modbusmaster be changed to decode modbus communication, even when it wasn't generated by itself?
My versions:
Modbus master 2.1.0.0
Windows 10 Home 21H2
I found a weasily little bug in ModbusLib which can cause some data corruption, specifically ModbusLib.Protocols.ModbusRtuCodec.ClientDecode(), where, if by chance, the data of a register read happens to contain an intermediate CRC for the packet, the ClientDecode will return CommResponseAck early, which then causes the SerialPortClient.Query() to exit its reception loop early, and thereby missing the remains of the message.
ie, I have logs which look like the following:
TX: 01 04 00 00 00 1a 71 c1
RX: 01 04 34 bf 31 5d 78 41 9a ed 42 47 bf f8 97 41 d9
26 registers were requested, but, by chance, my noisy data happened to land such that
"41 d9"
is the CRC for
"01 04 34 bf 31 5d 78 41 9a ed 42 47 bf f8 97"
so it exited early, ignoring the last 20 registers and treating the 6th as the CRC
This appears to be because the Codec ClientDecode function does not take into account the bytecount in the 3rd byte of the read operations response, though I suspect it is possible to occur for writes as well, just far less likely.
Both in master and salve ı cant choose the port name, what am ı doing wrong ?
Im using the Lib as Slave and Reading coils wont work. If i write a coil from the master to this Slave the coil datavalue is 65280, but the master cannot read it back.
Function 0x10 (write multiple holding registers) is missing for the slave while function 0x06 (write single holding register) is there. Why? I mean, as long as you've chosen "03 Holding Register" at the "Function" section of the application, I think both functions should be available in order not to be a little bit too restricted when you're going to write registers as you are now.
Hello, is there any Plan to include RTU over TCP?
See: https://www.simplymodbus.ca/TCP.htm
Or stephane/libmodbus#445
Best Regards,
Bernd
I use Modbus Slave as a simulator for a Quartz.Net scheduler, which reads Input Registers and Discrete Inputs every second. While it takes around 200 milliseconds for each job, when it reaches the 24th job it takes 5000 milliseconds for the Slave to respond. It does this even if I change the time interval for example to 3 seconds. Is there any limitation from the Slave that after some readings it adds a lag?
Thank you in advance.
Hey,
Is it possible to query slaves in parallel? The idea is that I am already connected and send two requests in parallel, then one request is not processed at all. Only if I make a delay between requests (min 95ms) then it will handle both requests. I've already set "Slave delay (ms)" to 0, but that didn't help. Is it a software fault or something on my side?
Would be really nice to have a update feature in the msi installer.
Installed version 2.0.2.2 to ModbusTool 2.0.3.0
If you have "Poll" checked, and then disconnect from the Modbus client, then the polling seems to continue and you're not able to disable it.
The log shows "Object reference not set to an instance of an object".
With a debugger, the exception comes from
ModbusTool/ModbusMaster/MasterForm.cs
Line 154 in b7e9237
Writes are denied, slave says:
Received address is not within viewable range, Received address: 1
See https://github.com/graham22/ModbusTool/blob/master/ModbusSlave/SlaveForm.cs#L340
Checks are always denied, because it's using https://github.com/graham22/ModbusTool/blob/master/CommonControls/BaseForm.cs#L20 which is always 0
I don´t know why, but there is nor field for entering an IP adress ?
Hello,
I have problems to know, what i have to type into the fields "start-Adress" and "size". I use the energy-meter-device B+G DS100 30B.
The Adresses are in the file. Which adresses i have to give in, when i want to get for example values for the first register (31025).
Is there a documentation?
Best regards
Thomas
Hey, I found a bug. When you try send request eg. with huge quantity then program will throw exception:
Application: ModbusSlave.exe Architecture version: v4.0.30319 Description: the process was
aborted due to an unhandled exception. Exception information:
System.OverflowException w
ModbusLib.Protocols.ModbusCodecReadMultipleRegisters.ServerDecode(ModbusLib.Protocols.ModbusCommand,
ModbusLib.ByteArrayReader) w
ModbusLib.Protocols.ModbusTcpCodec.ModbusLib.Protocols.IProtocolCodec.ServerDecode(ModbusLib.CommDataBase)
w ModbusLib.TcpServer.Worker() w
System.Threading.ExecutionContext.RunInternal(System.Threading.ExecutionContext,
System.Threading.ContextCallback, System.Object, Boolean) w
System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext,
System.Threading.ContextCallback, System.Object, Boolean) w
System.Threading.ExecutionContext.Run(System.Threading.ExecutionContext,
System.Threading.ContextCallback, System.Object) w
System.Threading.ThreadHelper.ThreadStart()
Example request 000100000006010363c09c85
I have installes the ModbusTool.msi file and double-clicked an icon. Nothing has happened.
I have Win 10 64bit, full update, dotnet framework 4.8.
What I am doing wrong?
Is there a user manual for non-coders?
Thank you!
A declarative, efficient, and flexible JavaScript library for building user interfaces.
🖖 Vue.js is a progressive, incrementally-adoptable JavaScript framework for building UI on the web.
TypeScript is a superset of JavaScript that compiles to clean JavaScript output.
An Open Source Machine Learning Framework for Everyone
The Web framework for perfectionists with deadlines.
A PHP framework for web artisans
Bring data to life with SVG, Canvas and HTML. 📊📈🎉
JavaScript (JS) is a lightweight interpreted programming language with first-class functions.
Some thing interesting about web. New door for the world.
A server is a program made to process requests and deliver data to clients.
Machine learning is a way of modeling and interpreting data that allows a piece of software to respond intelligently.
Some thing interesting about visualization, use data art
Some thing interesting about game, make everyone happy.
We are working to build community through open source technology. NB: members must have two-factor auth.
Open source projects and samples from Microsoft.
Google ❤️ Open Source for everyone.
Alibaba Open Source for everyone
Data-Driven Documents codes.
China tencent open source team.